Usted está aquí: casa > Radiografía>High Frequency Digital Radiography

High Frequency Digital Radiography

BT-PLD3600High Frequency Digital Radiography System


I. Application:

This machine is applied to take digital radiography on every part of human body, such as head, limbs, chest, limbus and abdomen and etc.

II.Specification:

Item

Content

Technical Parameter

Power Supply

Voltage

220V

Frequency

50Hz

Capacity

≥40kVA

internal resistor

≤0.15Ω

Generator



Power Output

32KW

Inverter Frequency

30 KHz

photography

Tube Voltage

40kV—150kV

Tube Current

10mA—320mA

Exposure time

1.0ms—6300ms

Digital Controlled X-ray Tube

Tube Focus

1.2mm /0.6mm(Large/Small Focus)

Input Power

Large/Small focus:40kW/20kW

Thermal capacity

110KJ

Rotary anode speed

2800rpm

Radiography Table

Table longitudinal movement

≥900mm

Table transverse movement

≥220mm

Pillar movementalong table

≥1300mm

Detectingholdermovement

≥500mm

Tube assembly up-down movement

500mm-1280mm

Collimator

Manual Multi-leaf

Table use fixed grid

Grid density:103L/INCH

Grid ratio:10:1

SID:120cm

Stationary type:15″×18″

Bucky Stand

Radio-graphic device movement along pillar

≥1300mm

Cassette SID

450-1780mm

Fixed grid

Grid density103L/INCH

Grid ratio:10:1

SID:180cm

Size:15″×18″

Flat Panel Detector

Vision size

358mm(H)×430 mm(V)

Pixel Matrix

2560(H)×3072(V)

Pixel Pitch

139 μm

Imaging time

less than 10s

Limiting resolution

3.5 lp/mm typ

A / D transform

14 bit

Energy range

40 - 150 kVp

Max input dose

(low transmission gain)

4 mR / frame

Date out

A 16-bit digital output Ethernet(1000BASE - T)

Command control

Ethernet(1000BASE - T)

Power input

DC 24V  4.8A

Work Station

CPU System

Brand:DELL OPTIPLEX 7010commercial use

Processor:Core™ i5-3570processor

RAM:4GB  DDR3

Hardware:500GB  SATA (7200 rpm)

CD-driver:suitMT’s16X variable-speed  DVD + / - RW With functions of double written

Network Card:Broadcom NetXtreme 10/100/1000 PCIe Gigabit LAN GNTB-A

High display card:1GB AMD RADEON HD 7570,FH,with DVI-VGA Adapter

Slop:PCIEseriel port and parallel port,all height,MT

Color LCD Monitor

19inches1M LEDbacking light LCD display

revolution1280x1024,5:4screen

dot pitch: 0.294mm

contrast ratio:1000:1

brightness:250cd/㎡

Grey feedback time: 5ms

visual Angle:160/170°

Monochrome Monitor(Optional)

1280*1024,19inches

brightness1000cd/m2

Contrast Ratio900:1

Work Station Software

Basic operation:

Change control console password, edit ID,acquisite images.

Additional operation:

Add new check, edit present checking info, add new position, change image aquisition order, multi-checking agreement chance, manual adjustment of exposure parameters, automatic exposure control mode, focus choice, patient body-type choice, tube capacity check, ESA curve choice, image cutting, note added (sent to DICOM workstation), mark on images, rotate or overturn, full-size image observation, check patient info and dose info, accept or refuse images.

Image management:

Change order, patient basic info editing, inquiry history images, resend history images, re-print history images, check images mark info, review history images, manage refused images, space reclaimed, image protection, and manual image deletion etc.

System management:

ID edition, change ID password, ED refrigeration set,statisticsinfo checking, detector calibration, equipment control, output order management, image measurement.