Usted está aquí: casa > Radiografía>Fixed x-ray>BT-XF19B Medical Diagnostic X-ray System

BT-XF19B Medical Diagnostic X-ray System

II. Standard Configuration:

1

Console

KZT40

1Unti

2

Generator

FSQ80

1Unit

3

X-ray tube

E7869X

1Unit

4

Collimator

XSQ20

1Unit

5

Diagnostic table

ZDC20

1Unit

6

Image intensifier

E5830SD-P6A

1Unit

7

CCD Camera

acA1920

1Unit

8

Digital image process system

DRFOC

1Unit

9

Flat Panel Detector

PLD1417V

1Unit

10

Medical use display

U2412Mc

1Unit

11

Cables and accessories

PLD8600

1Unit

 

III. Specifications:

Item

Content

Technical Parameters

Power Supply

Voltage

380V±38V

Frequency

50/60Hz±1Hz

Capacity

105kVA

Internal Resistance

≤0.11Ω

High frequency high voltage x-ray generator 

Power

80kW

Inverter Frequency

440 kHz

Tube voltage

40kV—150kV

Tube current

10mA—100mA

mAs

1.0ms—10000ms

Time

0.1 mAs1000 mAs

Fluoroscopy Tube Voltage

40kV—125kV

Fluoroscopy mA

0.5mA—10mA/ 5mA- 20mA

X-ray tube assembly

Tube Focus: big/small

1.2mm /0.6mm

Input power

Big Focus/100kW   Small focus/40kW

Anode thermal capacity

600KHU

Anode Rotation Speed

9700rpm

Micro-computer control digital tube remote diagnostic table

 

Table rotate Movement range

90°~0°~-25°

Table transverse movement distance

±110mm

Longitudinal movement distance of radiography frame and spot film device

≥720mm

SID

1100- 1500 mm

X-Ray tube focus to film distance

8″×10 ″- 14″×17″

Collimator         

Full film, half dividing, three parts dividing, four parts dividing

Fixed grid for table use

80N 130N

Table rotate Movement range

±360º  Infinite rotation

Table transverse movement distance

Electric multi-leaf

Longitudinal movement distance of radiography frame and spot film device

Grid density: 103L/INCH, Ratio: 10:1,

Focusing distance: 130cm,

stationary type :15” ×18”

Flat Panel Detector

Toshiba fixed Flat Panel Detector

Limiting resolution: 3.4 lp/mm typ

Vision size: 430(H)×439(V)

Pixel Matrix: 3008(H)×3072(V)

Pixel gap: 143 μm

A / D transform: 14 bit

DR Software

DRFOC

Basic operation: change control console password, edit ID, acquisite images.

Additional operation: Add new check, edit present checking info, add new position, change image aquisition order, multi-checking agreement chance, manual adjustment of exposure parameters, automatic exposure control mode, focus choice, patient body-type choice, tube capacity check, ESA curve choice, image cutting, note added (sent to DICOM workstation), mark on images, rotate or overturn, full-size image observation, check patient info and dose info, accept or refuse images.

Image management: change order, patient basic info editing, inquiry history images, resend history images, re-print history images, check images mark info, review history images, manage refused images, space reclaimed, image protection, and manual image deletion etc.

System management: ID edition, change ID password, ED refrigeration set, statistics info checking, detector calibration, equipment control, output order management, image measurement.

Digital Image TV System

Image Intensifier

230mm

high resolution CCD

ultra-low-light, standard 2 mega-pixel

Digital Picture Processing System

CCU Sentinel

High definition line by line output mode, 8 level noise reduction, store 8 image; LIH (freeze the last frame), the image can be turned vertically and horizontally, positive and negative image; OSDmonitor show

Gray scale display 19’’

resolution ratio:1280x1024

Luminance: 1000cd/

 

IV. Features

The floating table with bucky stand can meet the photographic requirements of different standing and lying positions. The bed floating and electromagnetic lock design makes it convenient for the accurate position of the lying patient, operation is much more convenient and flexible.

Digital flat Panel detector can help you get the high-definition images.

 

The leading domestic high power compact high frequency X-ray generator and high frequency power inverter makes the machine much more compact and more convenient without the extra high-voltage generator and cable.

The application of the KV and MA digital closed-loop control technology and the real time control of the microprocessor ensure the accuracy and repeatability of the dose.

The multiple automatic protection features and fault tips ensure safety during the operation process.

 

The system has excellent performance and high quality images, from the fluroscopy,spot film, sequence of all digital photography collected to digital subtraction angiography (DSA) image processing.

The table can be +90 degrees to 0 to -25 degrees rotate.

Humanized design of diagnosis bedside switch operation, can control the table body and imaging system movement,so that the close table inspection is convenient and easy operation.

Spot film device and imaging system movement range more than 720 mm.

Adopts the operation of the machine move, but the patient don't need move, can easily finish from the throat, esophagus to the lower abdomen of a series of inspections.

Cassette trolley can test cassette size by itself, a key can completely finish the insert piece, save space, convenient and fast.